How do you clear the trouble light on a DSC alarm?

The trouble light is an indication that something is not functioning properly on your DSC security system. When a trouble is present the system trouble indicator light will illuminate and the keypad will beep every 10 seconds. To silence the trouble beep simply press the # key on the keypad.

Why does my alarm system says trouble?

A trouble condition is an indication that there is something wrong with the alarm system. This could be a number of different things. Some possible causes of a trouble condition include a low battery, an unplugged wall outlet, an activated tamper cover or a problem with the communicator.

How do I find my DSC trouble code?

Your system will generate a trouble code that can be used to decipher the actual trouble condition. Press the ‘*’ followed by the number ‘2’. This will generate a small number in your display window. This number corresponds to the trouble condition on your system.

How do I reset my alarm system?

How Do I Reset My Alarm System?

  1. Disconnect the backup battery. Open up the system, and disconnect the backup battery.
  2. Unplug the transformer. Locate the transformer, and unplug it from the wall outlet.
  3. Power on. Plug the transformer and the battery back in.

Why would house alarm go off when not set?

If a fault is present you may find your alarm going off (sirens sound) by itself, even if unset. This can happen for a number of reasons, including a dead battery or faulty sensor. The information contained in this article will assist in shutting off the system and silence the sirens.

How to determine trouble condition on a DSc 1555 panel?

How to determine trouble condition on a DSC 1555 panel On Some DSC LCD Fixed keypads, a trouble is indicated by this symbol: which can be confused for the Medical Panic button. Here’s how to determine what the trouble condition is: Press *2 on the keypad. When a 7 is displayed, this indicates an RF Zone has a Low Battery.

What do the error lights on the pc5400 mean?

Lights 1 – 5 will light up to indicate the trouble: when the battery charges over 12.5 volts. • Light [2] Bell Circuit Trouble: The bell circuit is open (see section 5.13 “Bell” on page 23). • Light [3] General System Trouble: The printer connected to the PC5400 Printer module has a fault and is off-line.

How do I check for a trouble on my DSC LCD keypad?

On Some DSC LCD Fixed keypads, a trouble is indicated by this symbol: which can be confused for the Medical Panic button. Here’s how to determine what the trouble condition is: Press *2 on the keypad. Any of the numbers 1 – 8 may show up, indicating one or more of 8 possible trouble types . 1 = Service Required (See Below) 2 = AC Fail

Why won’t my DSC Wi-Fi turn on?

Go to the DSC website for the user manual for this system. Check the cover on your motion. It won’t clear unless the cover is on correctly. Check your batteries as well. DSC wireless, especially the older 900mhz units are fussy about batteries being fully charged.